Wholesale Three-Phase One-Position Electric Energy Meter Box TY-SXS1 - Reliable China Suppliers and Factory Solutions Manufacturers, Factory

The TY series three-phase single-digit electricity meter boxes, including models TY-SXS1-1H, TY-SXS1-NX1, TY-SXS1-1B, TY-SXS1-1C, TY-SXS1-1D, and TY-SXS1-1E, are manufactured in China by leading suppliers. These meter boxes are engineered to comply with stringent safety and reliability standards, boasting an insulation resistance of no less than 20MΩ and a rated insulation voltage of 800V. This ensures they effectively meet the demands of modern electrical systems. With compatibility for frequencies of 50Hz or 60Hz, these products offer versatile solutions for a variety of applications. Additionally, the meter box features a safety protection level of IP 44, providing excellent dust and water resistance, which contributes to their durability across different environments. As a trusted factory in China, we ensure our products uphold the highest quality standards in the industry

Product Description

Features Summary

Excellent Material

SMC glass fiber reinforced plastic molding, with high insulation (≥20MΩ), impact resistance (30KA short-term tolerance) and UL94 V-0 flame retardant performance.

Ultra-Long Life

Indoors >40 years / outdoors >30 years. Highly corrosion-resistant and anti-aging with a smooth and beautiful surface.

Flexible Application

Supports single-phase (220V) and three-phase (380V/690V) energy metering, current coverage 10A-250A, single-household/multi-household/cross-household combination installation.

Environmental Adaptability

Working temperature -25℃~+50℃, humidity ≤80% (at 40℃), IP44 protection level ensures outdoor rainproof.

Safety Specification

Comply with GB standard, insulation voltage 800V, frequency compatible with 50/60Hz.

Key Notes

  • The installation should be vertical (tilt ≤ 54°), away from corrosive chemicals (avoid strong alkali/ketones/chlorinated hydrocarbons).
  • Avoid direct sunlight and mechanical collision, and prefer a dry and vibration-free environment.
  • When installing, you need to remove the bottom screws first and fix the expansion tube according to the positioning holes.

TY-SXS1-1H Model, configuration and installation dimensions

TY SX S1 1 H
Company Code SMC non-metallic metering box Three-phase single-meter metering box Table number Eighth Generation
Configuration Name Component Model Quantity
Incoming switch Disconnector HD11F-100/38 100A 1
Outlet switch Leakage circuit breaker CDBLEK-125 4P li(C) 100A 1
TY-SXS1-1H

TY-SXS1-NX1 Model, configuration and installation dimensions

TY SX S1 NX1
Company Code SMC non-metallic metering box Three-phase single-meter metering box Ningxia
Configuration Name Component Model Quantity
Incoming switch Disconnector CDGK 4P 100A 1
Outlet switch Miniature circuit breakers CDBKs C type 4P 63A dedicated to power grid 1
TY-SXS1-NX1

TY-SXS1-1B Model, configuration and installation dimensions

TY SX S1 1 B
Company Code SMC non-metallic metering box Three-phase single-meter metering box Table number Second Generation
Configuration Name Component Model Quantity
Incoming switch Molded case circuit breaker CDMK-125C/3300 125A 1
Outlet switch Leakage circuit breaker CDBLEK-125 4P li(C)100A 1
TY-SXS1-1B

TY-SXS1-1C Model, configuration and installation dimensions

TY SX S1 1 C
Company Code SMC non-metallic metering box Three-phase single-meter metering box Table number Third Generation
Configuration Name Component Model Quantity
Incoming terminal Disconnector HD11F-100/38 100A 1
Outlet switch Leakage circuit breaker CDBLEK-125 4P li(C)100A 1
TY-SXS1-1C

TY-SXS1-1D Model, configuration and installation dimensions

TY SX S1 1 D
Company Code SMC non-metallic metering box Three-phase single-meter metering box Table number Fourth Generation
Configuration Name Component Model Quantity
Incoming switch Disconnector HD11F-200/48 200A 19CM 1
Outlet switch Molded case circuit breaker CDMK-250C/3300 200A 1
TY-SXS1-1D

TY-SXS1-1E Model, configuration and installation dimensions

TY SX S1 1 E
Company Code SMC non-metallic metering box Three-phase single-meter metering box Table number Fifth Generation
Configuration Name Component Model Quantity
Incoming terminal Disconnector HD11F-200/48 200A 19CM 1
Outlet switch Molded case circuit breaker CDMK-250C/3300 200A 1
TY-SXS1-1E

Frequently Asked Questions

What material is used for the TY series meter box, and what are its properties?

The TY series meter box is made using SMC glass fiber reinforced plastic molding. It features high insulation (≥20MΩ), impact resistance (30KA short-term tolerance), and UL94 V-0 flame retardant performance.

What is the expected lifespan of these fiberglass meter boxes?

These boxes offer an ultra-long service life. They are designed to last more than 40 years indoors and more than 30 years outdoors, thanks to their corrosion-resistant and anti-aging properties.

What are the main installation environment requirements?

The meter boxes should be installed vertically (tilt ≤ 54°) in a dry, vibration-free environment away from direct sunlight. They must also be kept away from corrosive chemicals like strong alkalis, ketones, and chlorinated hydrocarbons.

What are the electrical specifications and power configurations supported?

The TY series supports single-phase (220V) and three-phase (380V/690V) energy metering. It covers currents from 10A to 250A, has an insulation voltage of 800V, and is compatible with 50/60Hz frequencies.

How does the meter box adapt to harsh outdoor weather conditions?

It features an IP44 protection level which ensures outdoor rainproof performance. It functions reliably in working temperatures ranging from -25℃ to +50℃, and humidity levels up to 80% (at 40℃).

What is the correct procedure to mount the TY series meter box?

When installing the box, you must first remove the bottom screws, and then fix the expansion tube securely according to the pre-designed positioning holes.